Equipment
Inverted Confocal Laser Scanning Microscope - TCS SP8 STED CW
| Model | TCS SP8 STED CW (*STED function not available) |
|---|---|
| Manufacturer | Leica Microsystems (Germany) |
| Year Introduced | 2012 |
| Usage Type | Analysis request (paid), Personal use (paid) |
| Features | 4 channels, Laser (405, 488, 561, 594, 633nm), LAS-X S/W |
| Usage Guidelines | Reservation via the online reservation system or by phone · Cancellation is allowed up to 1 hour before the reserved time; cancellations after that incur a penalty, and no-shows are charged the full usage fee for the reserved time |
| Location | Medical Research Innovation Center (CMI), Room B2307-1 |
Inverted Confocal Laser Scanning Microscope - TCS SP8
| Model | TCS SP8 |
|---|---|
| Manufacturer | Leica Microsystems (Germany) |
| Year Introduced | 2015 |
| Usage Type | Analysis request (paid), Personal use (paid) |
| Features | 4 channels, Laser (405, 488, 561, 633nm), LAS-X S/W |
| Usage Guidelines | Reservation via the online reservation system or by phone · Cancellation is allowed up to 1 hour before the reserved time; cancellations after that incur a penalty, and no-shows are charged the full usage fee for the reserved time |
| Location | Medical Research Innovation Center (CMI), Room B2307-2 |
Upright Confocal Laser Scanning Microscope - STELLARIS 8
| Model | STELLARIS 8 |
|---|---|
| Manufacturer | Leica Microsystems (Germany) |
| Year Introduced | 2021 |
| Usage Type | Analysis request (paid), Personal use (paid) |
| Features | 5 channels, White Light Spectral Laser (405nm, 440~790nm), LAS-X S/W |
| Usage Guidelines | Reservation via the online reservation system or by phone · Cancellation is allowed up to 1 hour before the reserved time; cancellations after that incur a penalty, and no-shows are charged the full usage fee for the reserved time |
| Location | Medical Research Innovation Center (CMI), Room B2307-2 |
Inverted Confocal Laser Scanning Microscope - STELLARIS WLL PLUS
| Model | STELLARIS WLL PLUS |
|---|---|
| Manufacturer | Leica Microsystems (Germany) |
| Year Introduced | 2026 |
| Usage Type | Analysis request (paid), Personal use (paid) |
| Features | 5 channels, White Light Spectral Laser (405nm, 485~790nm), LAS-X S/W |
| Usage Guidelines | Reservation via the online reservation system or by phone · Cancellation is allowed up to 1 hour before the reserved time; no-shows are charged the full usage fee for the reserved time |
| Location | Medical Research Innovation Center (CMI), Room B2307-2 |
Tissue Clearing System - X-Clarity Tissue Clearing System II
| Model | X-Clarity Tissue Clearing System II |
|---|---|
| Manufacturer | Logos Biosystems (Korea) |
| Year Introduced | 2018 |
| Usage Type | Analysis request (paid), Personal use (paid) |
| Features | Hydrogel-based tissue clearing · Rapidly and efficiently removes lipids within tissue to enable 3D imaging |
| Usage Guidelines | Advance phone reservation · Cancellation is allowed up to 1 hour before the reserved time; cancellations after that incur a penalty, and no-shows are charged the full usage fee for the reserved time |
| Location | Medical Research Innovation Center (CMI), Room B2307-2 |